Summary for Test 2019-05-29-2-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout DateNot set
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date05/29/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/04/2019
Sample typeQuality Assurance A brief description of the sampleHeaded Bars
The quantity of what the sample constitutes1 lot From where was the sample collectedFabricator
First name of sampler or witnessed byHitesh Last name of sampler or witnessed byPatel
Title of samplerQuality Assurance Inspector Telephone number of sampler9168691602
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL131-102-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)189111,73112680 Rebar Heat Number(s)033688
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2019-05-29-2
DIME Test ID: 2019-05-29-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-06-11

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 06/03/2019
UTM: 2000kip
Halo ID: Large
Temperature: 72.00 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
132No. 11/36mm1.56014972595978Bar Broke, Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Bar Broke, Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 6/4/2019