Summary for Test 2019-05-23-14-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213229
DEA: 050A0504
EFIS: 0500000007
DIST-CO-RTE-PM05-SB-1-15.6
Award Date12/14/2018
Closeout Date08/17/2022
Work DescriptionBRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE.
Location DescriptionSANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE
QA Service Level1 (Verified on 03/23/2018)

Sample Information

Sample Taken Date05/23/2019 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2019
Sample typeQuality Assurance A brief description of the sample D101A Bar Splice
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byRose
Title of sampler Telephone number of sampler
Laboratory sample identificationLot 1 And 2 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNucor Dayton Superior Transportation Laboratory (TL) NumberC760339
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelD101A
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)D101A Rebar Heat Number(s)3100000982
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2019-05-23-14
DIME Test ID: 2019-05-23-14-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-06-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/31/2019
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#5/16mm0.3103030697761Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/31/2019