Test 2019-04-29-12-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213720
DEA: 024H2004
EFIS: 0218000094
DIST-CO-RTE-PM02-SHA-89-26.3/29.2
Work DescriptionPAVEMENT OVERLAY
Location DescriptionSHASTA COUNTY ABOUT 10 MILES NORTH OF BURNEY FROM 0.3 MILE NORTH OF CLARK CREEK ROAD TO LAKE BRITTON BRIDGE
Sample Information
Sample Taken Date4/29/2019 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/29/2019
Sample typeVerification A brief description of the sample3/4-inch Untreated Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of sampler Laboratory sample identificationD77857A_19-CHMA-0097
The fabricator/manufacturer/facility nameShaw pit Transportation Laboratory (TL) Number001581
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-25-0008::SHAW PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample19-1278.105A
The plant numberUnknown A detailed description of where the material sample was collectedSized Untreated Aggregate Stockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 19-04-S2 Lot number0
Sublot number0 JMF Verification ID
Test Details
DIME Sample ID: 2019-04-29-12
DIME Test ID: 2019-04-29-12-1
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-05-30
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 04/30/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:95.7 %
Cumulative percent passing the 1/2 in. sieve:29.4 %
Cumulative percent passing the 3/8 in. sieve:4.9 %
Cumulative percent passing the 1/4 in. sieve:1.6 %
Cumulative percent passing the #4 sieve:1.4 %
Cumulative percent passing the #8 sieve:1.2 %
Cumulative percent passing the #16 sieve:1.1 %
Cumulative percent passing the #30 sieve:1.1 %
Cumulative percent passing the #50 sieve:1 %
Cumulative percent passing the #100 sieve:0.9 %
Cumulative percent passing the #200 sieve:0.84 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/30/2019