Summary for Test 2019-05-08-17-2

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 213306
DEA: 07303404
EFIS: 0714000006
DIST-CO-RTE-PM07-VEN-33-0.0/6.3
Award Date06/18/2018
Closeout Date05/10/2021
Work DescriptionCOLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT
Location DescriptionVENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE
QA Service Level1 (Verified on 12/09/2020)

Sample Information

Sample Taken Date05/08/2019 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/10/2019
Sample typeVerification A brief description of the sample1/2 RHMA-G-SP
The quantity of what the sample constitutesPSE 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Saticoy Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0274G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility namePalmdale, Big Rock Creek, Blvd, Sheldon Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample326120 SAT LTR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-05-08-17
DIME Test ID: 2019-05-08-17-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2019-06-06

Test Results


Method: 2 - Individual Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 05/16/2019
Weighted average percentage of fractured, coarse, 2 faced particles: 97 %
Weighted average percentage of fractured, coarse, 1 faced particles: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/30/2019