Test 2019-04-17-27-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213720
DEA: 024H2004
EFIS: 0218000094
DIST-CO-RTE-PM02-SHA-89-26.3/29.2
Work DescriptionPAVEMENT OVERLAY
Location DescriptionSHASTA COUNTY ABOUT 10 MILES NORTH OF BURNEY FROM 0.3 MILE NORTH OF CLARK CREEK ROAD TO LAKE BRITTON BRIDGE
Sample Information
Sample Taken Date4/17/2019 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/18/2019
Sample typeVerification A brief description of the sample1/2-inch Type A Aggregate (Virgin)
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of sampler Laboratory sample identificationD77833A
The fabricator/manufacturer/facility nameShaw Pit Facility Transportation Laboratory (TL) Number853332
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-25-0008::SHAW PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample19-1278.105B
The plant numberUnknown A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 19-05-S1a Lot number0
Sublot number0 JMF Verification ID JMF3513-2019-60
Test Details
DIME Sample ID: 2019-04-17-27
DIME Test ID: 2019-04-17-27-1
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-05-13
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Measured
Tester's full name: Colt Sweeny and T. McCormick
Date of test: 04/22/2019
Total mass of material in the sample: 3196.6 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 275 grams
Cumulative mass retained on the 3/8 in. sieve: 719 grams
Mass retained on the 1/4 in. sieve: 1171 grams
Cumulative mass retained on the #4 sieve: 1448 grams
Total sample mass passing the #4 sieve: 1748.6 grams
Total mass of fine material in the sample: 508.6 grams
Cumulative mass retained on the #8 sieve: 194 grams
Cumulative mass retained on the #16 sieve: 308 grams
Cumulative mass retained on the #30 sieve: 366.3 grams
Cumulative mass retained on the #50 sieve: 400.9 grams
Cumulative mass retained on the #100 sieve: 422.3 grams
Cumulative mass retained on the #200 sieve: 438.3 grams
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:91.4 %
Cumulative percent passing the 3/8 in. sieve:77.5 %
Cumulative percent passing the 1/4 in. sieve:63.4 %
Cumulative percent passing the #4 sieve:54.7 %
Cumulative percent passing the #8 sieve:33.8 %
Cumulative percent passing the #16 sieve:21.6 %
Cumulative percent passing the #30 sieve:15.3 %
Cumulative percent passing the #50 sieve:11.6 %
Cumulative percent passing the #100 sieve:9.3 %
Cumulative percent passing the #200 sieve:7.56 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/13/2019