Summary for Test 2019-05-06-8-10
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212867 DEA: 033F9204 EFIS: 0313000239 |
---|---|
DIST-CO-RTE-PM | 03-NEV-80-19.1,27.4 |
Award Date | 02/12/2018 |
Closeout Date | 05/05/2020 |
Work Description | REPLACE SAND AND SALT HOUSES. |
Location Description | NEVADA COUNTY IN TRUCKEE AT THE DONNER PASS INSPECTION FACILITY AND AT FLORISTON AT THE FLORISTON SAND AND SALT HOUSES |
QA Service Level | 1 (Verified on 12/18/2017) |
Sample Information
Sample Taken Date | 05/06/2019 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/09/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolts |
The quantity of what the sample constitutes | 56 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Hitesh | Last name of sampler or witnessed by | Patel |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cardova Gaffney Nucor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 62147915-03 NF16100618 100793065 NF14204642 100890613 100889371 DL16102863 188308 DL15106143 DL18101168 DL14102388 NF13104701 B46227 416992 9514538 R4253A B48499 | Nut Mfg. Lot Number(s) | 28306 369951B 40666A 352617B 410454B |
Washer Mfg. Lot Number(s) | 0218-754 030711 032515 029511 0818-923 | Bolt Specification | A325 A325TC HDG |
Bolt Length(s) | 3" 2.5" 2" 2.75" 1.5" 2.25" 5.5" | Nut Specification | A563 HDG |
Washer Specification | F436 HDG | Finish | HDG |
Diameter/Size | 1.5 .75 .625 | Bolt Mfg. Lot Number | 49095 375215A 409104A 354491A 416145A 403053A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-05-06-8
DIME Test ID: 2019-05-06-8-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-05-21
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 05/13/2019
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 6A | 403053A | 5/8\" | 31984 | 142.3 | 10 | A325 | Steve |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 5/14/2019 ✔