Summary for Test 2019-05-08-2-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212245
DEA: 024F8604
EFIS: 0213000043
DIST-CO-RTE-PM02-TRI-36-26.7/27.1
Award Date11/02/2018
Closeout Date05/23/2022
Work DescriptionROADWAY REALIGNMENT AND NEW BRIDGE CONSTRUCTION
Location DescriptionTRINITY COUNTY ABOUT 9 MILES EAST OF FOREST GLEN FROM 0.6 MILE WEST TO 0.1 MILE WEST OF ROUTE 3
QA Service Level1 (Verified on 03/21/2017)

Sample Information

Sample Taken Date05/08/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/09/2019
Sample typeQuality Assurance A brief description of the sample#11 Rebar Couplers
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of samplerAssociate Steel Inspector Telephone number of sampler(510) 385-5910
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) Number741534
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-019-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarTec Intermediate Assembler or Fabricator
Rebar Size11 Coupler ModelBartec
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)8295879 Rebar Heat Number(s)1202002192
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2019-05-08-2
DIME Test ID: 2019-05-08-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-05-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/10/2019
UTM: 2000kip
Halo ID: Large
Temperature: 72.00 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121No. 11/36mm1.56014588893518fsaylor

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 5/10/2019