Test 2019-04-04-17-11 (CTM 643-June 2007) Summary

Project Information
Project IdentifiersProject ID: 214135
DEA: 09213404
EFIS: 0900000034
DIST-CO-RTE-PM09-INY-395-29.9/41.8
Work DescriptionROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location DescriptionINYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
Sample Information
Sample Taken Date4/4/2019 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/10/2019
Sample typePer Request A brief description of the sampleNative Material
The quantity of what the sample constitutes2 bags From where was the sample collectedJob Site
First name of sampler or witnessed byDereck Last name of sampler or witnessed byCarrington
Title of sampler Laboratory sample identification8543
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberC448817
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedExisiting Grade
Where the material sample would have been placed if not sampledUnknown
Test Details
DIME Sample ID: 2019-04-04-17
DIME Test ID: 2019-04-04-17-11
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-06-06
Test Results

The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Friday Ofoegbu
Date of test: 04/13/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 16000 Ohms
Soil sample temperature: 20.6 C
Soil box constant: 1
pH of soil: 7.22
Minimum soil resistance corrected to 15.5:18840 Ohms
Minimum soil resistivity at 15.5:18840 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/30/2019