Test 2019-04-01-27-2 (AASHTO T315-12) Summary

Project Information
Project IdentifiersProject ID: 212753
DEA: 020H7604
EFIS: 0215000086
DIST-CO-RTE-PM02-LAS,PLU-VAR-VAR
Work DescriptionFULL DEPTH RECLAMATION AND DRAINAGE REHABILITATION
Location DescriptionLASSEN AND PLUMAS COUNTIES AT AND NEAR CHILCOOT FROM 0.9 MILE WEST OF SUMMIT SCHOOL DRIVE TO 0.7 MILE EAST OF ROUTE 395
Sample Information
Sample Taken Date4/1/2019 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Control A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutesproduction From where was the sample collectedManufacturer
First name of sampler or witnessed byTed Last name of sampler or witnessed byKinsey
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameValero-Benicia Asphalt Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot numberNot set
Sublot numberNot set HMA Design ID JMF3512-2019-98-19-1278.106
Test Details
DIME Sample ID: 2019-04-01-27
DIME Test ID: 2019-04-01-27-2
Testing Lab: CGI Technical Services, Inc.
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2019-05-08
Test Results

Input Type: Calculated
Tester's full name: Ted Kinsey
Date of test: 04/01/2019
Phase: RTFO residue
Phase Angle (δ) (for the 10 cycles): 1.0 degree
Dynamic Shear, G*/sin(δ):2.53 kPa
(G*) x sin(δ)=:no data
General comments (publicly viewable) (Max 250 characters):

Test was verified on 05/08/2019