Summary for Test 2019-04-17-12-2

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 213788
DEA: 120Q5204
EFIS: 1217000057
MINOR: 12A1741
DIST-CO-RTE-PM12-ORA-12,133-8.29
Award DateNot set
Closeout DateNot set
Work DescriptionRemove seven electroliers, install high-mast lighting ,asphalt and optical speed bar and Install safety lighting & optical speed bar
Location DescriptionRoute 133
QA Service Level1 (Verified on 01/16/2019)

Sample Information

Sample Taken Date04/17/2019 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/20/2019
Sample typeQuality Assurance A brief description of the sampleF1554 Anchor Rod, Nut, Washers
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameEDSCO Fasteners Transportation Laboratory (TL) NumberC720609
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-051-19 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3084898 Nut Mfg. Lot Number(s)DDYO HDG, DDYC Plain
Washer Mfg. Lot Number(s)308878 Bolt SpecificationF1554 Gr 55
Bolt Length(s)4'-5" Nut SpecificationA194
Washer SpecificationF436 FinishHDG, Plain
Diameter/Size2 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-04-17-12
DIME Test ID: 2019-04-17-12-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-05-10

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 05/02/2019
UTM: 67KIP
Temperature: 72 f
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1230848980.5010.197695569243025.6Steve

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/3/2019