Summary for Test 2019-04-25-3-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 213527
DEA: 081E5604
EFIS: 0814000050
DIST-CO-RTE-PM08---
Award Date11/19/2018
Closeout Date06/23/2021
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date04/25/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP
The quantity of what the sample constitutesPSE 12 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVMC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0247A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Oro Grande Transportation Laboratory (TL) Number030391
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0137, 91-36-0042
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R-15 The fabricator/manufacturer designation for the sample224112 ORO SJR
The plant numberUnknown A detailed description of where the material sample was collectedMaunfacturer
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-04-25-3
DIME Test ID: 2019-04-25-3-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-05-15

Test Results


Input Type: Measured
Tester's full name: Sebastian Ferrer
Date of test: 04/30/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 967.2 grams
Mass of the pycnometer with water (B): 653.8 grams
Mass of the oven dried sample (before pycnometer) (A): 494.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 494.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.649
Bulk specific gravity (SSD Basis): 2.680
Apparent specific gravity: 2.732
Absorption: 1.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/8/2019