Summary for Test 2017-04-03-20-7

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 213793
DEA: 060W7004
EFIS: 0617000283
DIST-CO-RTE-PM06-FRE-33-24.3/R29.0,R39.9/44.5
Award Date01/24/2019
Closeout Date08/20/2021
Work DescriptionCOLD PLANE AC PAVEMENT, PLACE HMA RESURFACING.
Location DescriptionFRESNO COUNTY ABOUT 7.8 MILES NORTH OF COALINGA FROM NORTH JUNCTION ROUTE 198 TO SOUTH JUNCTION ROUTE 33/5 AND FROM 0.1 MILE NORTH OF NORTH JUNCTION ROUTE 33/5 TO EL PROGRESSIO ROAD
QA Service Level1 (Verified on 01/09/2019)

Sample Information

Sample Taken Date04/03/2017 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/03/2017
Sample typeQuality Control A brief description of the sample1/2 inch Type A (PG 64-10) (Dispute Resolution)
The quantity of what the sample constitutesJMF HMA Design Data (Dispute Resolution) From where was the sample collectedSource
First name of sampler or witnessed bySPM Last name of sampler or witnessed byAvenal
Title of samplerNA Telephone number of sampler805-473-3016
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPM-Avenal Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2017-04-03-20
DIME Test ID: 2017-04-03-20-7
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2019-05-08

Test Results


Input Type: Calculated
Tester's full name: G3 Quality, Inc.
Date of test: 04/03/2017
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 10000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 10000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 7.62 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 5.08 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
General comments (publicly viewable) (Max 1000 characters): JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.

Test was verified on 5/1/2019