Test 2017-04-03-20-7 (AASHTO T324-14) Summary

Project Information
Project IdentifiersProject ID: 213793
DEA: 060W7004
EFIS: 0617000283
DIST-CO-RTE-PM06-FRE-33-24.3/R29.0,R39.9/44.5
Work DescriptionCOLD PLANE AC PAVEMENT, PLACE HMA RESURFACING.
Location DescriptionFRESNO COUNTY ABOUT 7.8 MILES NORTH OF COALINGA FROM NORTH JUNCTION ROUTE 198 TO SOUTH JUNCTION ROUTE 33/5 AND FROM 0.1 MILE NORTH OF NORTH JUNCTION ROUTE 33/5 TO EL PROGRESSIO ROAD
Sample Information
Sample Taken Date4/3/2017 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/3/2017
Sample typeQuality Control A brief description of the sample1/2 inch Type A (PG 64-10) (Dispute Resolution)
The quantity of what the sample constitutesJMF HMA Design Data (Dispute Resolution) From where was the sample collectedSource
First name of sampler or witnessed bySPM Last name of sampler or witnessed byAvenal
Title of samplerNA Laboratory sample identification
The fabricator/manufacturer/facility nameSPM-Avenal Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Design ID JMF3512-2019-97-17-137
Test Details
DIME Sample ID: 2017-04-03-20
DIME Test ID: 2017-04-03-20-7
Testing Lab: CT HQ - Hot Mix Asphalt Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2019-05-08
Test Results

Input Type: Calculated
Tester's full name: G3 Quality, Inc.
Date of test: 04/03/2017
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:no data
Impression at specified number of passes average:no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A):10000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B):10000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A):7.62 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B):5.08 mm
Stripping Inflection Point (Wheel A):0
Stripping Inflection Point (Wheel B):0
General comments (publicly viewable) (Max 1000 characters): JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.

Test was verified on 05/01/2019