Test 2019-04-15-8-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 213651
DEA: 08388524
EFIS: 0812000124
DIST-CO-RTE-PM08-SBD-330-32.3/32.6,33.4/33.8
Work DescriptionREPLACE BRIDGE RAILS AND APPROACH RAILS.
Location DescriptionSAN BERNARDINO COUNTY FROM 0.2 MILE SOUTH TO 0.1 MILE NORTH OF CITY CREEK BRIDGE AND FROM 0.3 MILE SOUTH TO 0.1 MILE NORTH OF EAST CITY CREEK BRIDGE
Sample Information
Sample Taken Date4/15/2019 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/18/2019
Sample typeVerification A brief description of the sample1/2 HMA-A-SP
The quantity of what the sample constitutesJMF 6 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0240A-19
The fabricator/manufacturer/facility nameVulcan - Corona, Pacific Clay Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0027::CORONA QUARRY
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP The fabricator/manufacturer designation for the sample324108 CORD SJR
The plant numberUnknown A detailed description of where the material sample was collectedManufacturer
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-04-15-8
DIME Test ID: 2019-04-15-8-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-05-07
Test Results

Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 04/24/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 966.5 grams
Mass of the pycnometer with water (B): 655 grams
Mass of the oven dried sample (before pycnometer) (A): 493.4 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 493.4 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.618
Bulk specific gravity (SSD Basis):2.653
Apparent specific gravity:2.712
Absorption:1.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/30/2019