Summary for Test 2019-04-08-7-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 209694
DEA: 080J0704
EFIS: 0800000282
DIST-CO-RTE-PM08-SBD-215-0.6/1.7
Award Date10/17/2017
Closeout Date04/23/2020
Work Description(Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA.
Location DescriptionGrade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60.
QA Service Level1 (Verified on 12/11/2017)

Sample Information

Sample Taken Date04/08/2019 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/24/2019
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byEDDY Last name of sampler or witnessed bySCOTT
Title of samplerASR Telephone number of sampler
Laboratory sample identification975-408A Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertson Riverside Transportation Laboratory (TL) Number20190408A
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierabutment 1 stage 2 footing
Structure nameabutment 1 stage 2 footing

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected146 The batch plant ticket number from where the sample was collected4369261
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleMYERS
A detailed description of where the material sample was collected95 cy Where the material sample would have been placed if not sampledabutment 1 stage 2 footing
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-04-08-7
DIME Test ID: 2019-04-08-7-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2019-04-29

Test Results


Number of specimens: 2
Input Type: Calculated
Tester's full name: Matthew Clayton
Date of test: 04/29/2019
Correction factor: 1
Cylinder Age: 21 days
Break Description of Cylinder 1 (if not 'cone'): 1
Break Description of Cylinder 2 (if not 'cone'): 1
Average Compressive Strength (to nearest 10): 3830 lb/in^2
Compressive Strength of Cylinder 1: 3820 lb/in^2
Compressive Strength of Cylinder 2: 3830 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/29/2019