Summary for Test 2019-04-16-22-8

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 212872
DEA: 07302204
EFIS: 0713000481
DIST-CO-RTE-PM07-VEN-126-0.0/R13.6
Award Date01/24/2018
Closeout Date05/26/2022
Work DescriptionPLACE HOT MIX ASPHALT AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY IN VENTURA AND SANTA PAULA FROM ROUTE 126/101 SEPARATION TO HAUN CREEK BRIDGE
QA Service Level1 (Verified on 04/27/2020)

Sample Information

Sample Taken Date04/16/2019 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/22/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesPSE 8 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byJay Last name of sampler or witnessed byOlsen
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identification0242G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Sun Valley Transportation Laboratory (TL) Number002802
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample226108 SVA3 SJR
The plant number3 A detailed description of where the material sample was collectedManufacturer
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-04-16-22
DIME Test ID: 2019-04-16-22-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-05-07

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 04/26/2019
Bulk dry specific gravity: 2.644
Average uncompacted voids: 46.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/30/2019