Test 2019-04-24-9-1 (AASHTO T209-12) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date4/24/2019 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/24/2019
Sample typeAggregate Prequalification Program A brief description of the samplefor JMF verification
The quantity of what the sample constitutes24 boxes From where was the sample collectedSource
First name of sampler or witnessed byEscobar Last name of sampler or witnessed byEscobar
Title of samplerQC Operations Supervisor Laboratory sample identification
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2019-04-24-9
DIME Test ID: 2019-04-24-9-1
Testing Lab: Granite Construction - Tracy
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-04-24
Test Results

Number of tests: 1
Mass Determination: Water
Input Type: Calculated
Tester's full name: Javier Macias
Date of test: 02/11/2019
Specific Gravity for Sample 1:2.486
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/24/2019