Test 2019-04-10-17-6 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 212512
DEA: 120M9604
EFIS: 1213000068
DIST-CO-RTE-PM12-ORA-73-22.5/25.7
Work DescriptionCOLDPLANE AC PVMTS , UPGRADE MBGR, CURB RAMPS AND CRASH CUSHION.
Location DescriptionIRVINE AND NEWPORT BEACH FROM BONITA CANYON DRIVE/FORD ROAD UNDERCROSSING TO 0.2 MILE SOUTH OF RED HILL AVENUE OVERCROSSING
Sample Information
Sample Taken Date4/10/2019 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/15/2019
Sample typeVerification A brief description of the sample1/2 OGFC
The quantity of what the sample constitutesJMF 3 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byRJ Last name of sampler or witnessed byNoble Company
Title of sampler Laboratory sample identification0230O-19
The fabricator/manufacturer/facility nameHanson Aggregates Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0035::EAGLE VALLEY QUARRY
The fabricator's/manufacturer's product name for the sample1/2 OGFC PG 64-10 The fabricator/manufacturer designation for the sample43R001SPO
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-04-10-17
DIME Test ID: 2019-04-10-17-6
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-05-07
Test Results

Input Type: Measured
Tester's full name: Michael Magana
Date of test: 04/22/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 966.3 grams
Mass of the pycnometer with water (B): 651.1 grams
Mass of the oven dried sample (before pycnometer) (A): 492.4 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 492.4 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.665
Bulk specific gravity (SSD Basis):2.706
Apparent specific gravity:2.779
Absorption:1.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/30/2019