Test 2019-04-10-16-5 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 213584
DEA: 074W2804
EFIS: 0718000113
DIST-CO-RTE-PM07-VEN-33-6.3/11.2
Work DescriptionAPPLY SLURRY SEAL COAT AND REPLACE ASPHALT CONCRETE SURFACING.
Location DescriptionVENTURA COUNTY NEAR VENTURA FROM 0.1 MILE SOUTH OF PARKVIEW DRIVE TO ROUTE 150
Sample Information
Sample Taken Date4/10/2019 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/15/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP
The quantity of what the sample constitutesPSE 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byEzequiel Last name of sampler or witnessed byOrtega
Title of samplerGranit QC Technician Laboratory sample identification0227A-19
The fabricator/manufacturer/facility nameGranite - Santa Paula Transportation Laboratory (TL) Number913399
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0008::LITTLEROCK
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP The fabricator/manufacturer designation for the sample2126
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at 100 Tons
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-04-10-16
DIME Test ID: 2019-04-10-16-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-04-30
Test Results

Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 04/16/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 992.1 grams
Mass of the pycnometer with water (B): 675.4 grams
Mass of the oven dried sample (before pycnometer) (A): 496.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 496.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.708
Bulk specific gravity (SSD Basis):2.728
Apparent specific gravity:2.763
Absorption:0.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/23/2019