Summary for Test 2019-03-25-18-7

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 213691
DEA: 074W2904
EFIS: 0718000114
DIST-CO-RTE-PM07-VEN-118-0.4/11.0
Award Date12/04/2018
Closeout Date02/20/2020
Work DescriptionREPLACE ASPHALT CONCRETE SURFACING AND APPLY SLURRY SEAL COAT.
Location DescriptionVENTURA COUNTY IN VENTURA FROM 0.2 MILE WEST OF ROUTE 118/126 SEPARATION TO ROUTE 34
QA Service Level1 (Verified on 02/20/2020)

Sample Information

Sample Taken Date03/25/2019 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/27/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP
The quantity of what the sample constitutesPSE 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Materials Last name of sampler or witnessed byVulcan Materials
Title of sampler Telephone number of sampler
Laboratory sample identification0203A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSheldon Boulevard Big Rock Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017::SHELDON
The fabricator's/manufacturer's product name for the sample220831 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedManufaturer
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-25-18
DIME Test ID: 2019-03-25-18-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-04-30

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 04/02/2019
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/23/2019