Test 2019-03-22-8-2 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213309
DEA: 081H0904
EFIS: 0816000141
DIST-CO-RTE-PM08-RIV-15-43.5
Work DescriptionCONSTRUCT A SECOND LEFT-TURN LANE
Location DescriptionRIVERSIDE COUNTY IN NORCO AT SECOND STREET UNDERCROSSING.
Sample Information
Sample Taken Date3/22/2019 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/26/2019
Sample typeVerification A brief description of the sample3/4" RHMA-G-SP Aggregate
The quantity of what the sample constitutesJMF 6 Bags From where was the sample collectedFabricator
First name of sampler or witnessed byAAA Corona QC Last name of sampler or witnessed byAAA Corona QC
Title of sampler Laboratory sample identification0199G-19
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample106835 The fabricator/manufacturer designation for the sampleUnknown
The plant numberCorona A detailed description of where the material sample was collectedBelt cut of Coarse and Fine Aggregate at Source
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-03-22-8
DIME Test ID: 2019-03-22-8-2
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-05-15
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Measured
Tester's full name: Husni Ankir
Date of test: 03/27/2019
Total mass of material in the sample: 50199 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 1406 grams
Cumulative mass retained on the 1/2 in. sieve: 8946 grams
Cumulative mass retained on the 3/8 in. sieve: 19310 grams
Mass retained on the 1/4 in. sieve: 19310 grams
Cumulative mass retained on the #4 sieve: 37527 grams
Total sample mass passing the #4 sieve: 12672 grams
Total mass of fine material in the sample: 510 grams
Cumulative mass retained on the #8 sieve: 250 grams
Cumulative mass retained on the #16 sieve: 331 grams
Cumulative mass retained on the #30 sieve: 376 grams
Cumulative mass retained on the #50 sieve: 407 grams
Cumulative mass retained on the #100 sieve: 432 grams
Cumulative mass retained on the #200 sieve: 451 grams
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:97.2 %
Cumulative percent passing the 1/2 in. sieve:82.2 %
Cumulative percent passing the 3/8 in. sieve:61.5 %
Cumulative percent passing the 1/4 in. sieve:61.5 %
Cumulative percent passing the #4 sieve:25.2 %
Cumulative percent passing the #8 sieve:12.8 %
Cumulative percent passing the #16 sieve:8.8 %
Cumulative percent passing the #30 sieve:6.6 %
Cumulative percent passing the #50 sieve:5.1 %
Cumulative percent passing the #100 sieve:3.9 %
Cumulative percent passing the #200 sieve:2.92 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/08/2019