Summary for Test 2019-04-05-12-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 212956 DEA: 080R3404 EFIS: 0812000072 |
---|---|
DIST-CO-RTE-PM | 08-SBD-38-30.9 |
Award Date | 03/06/2018 |
Closeout Date | 09/30/2019 |
Work Description | BRIDGE REHABILITATION AND UPGRADE BRIDGE RAILING TO STANDARDS |
Location Description | SAN BERNARDINO COUNTY NEAR ANGELUS OAKS AT SANTA ANA RIVER BRIDGERAM |
QA Service Level | 1 (Verified on 05/09/2018) |
Sample Information
Sample Taken Date | 04/05/2019 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/05/2019 |
Sample type | Quality Assurance | A brief description of the sample | HMWM |
The quantity of what the sample constitutes | 1qt. | From where was the sample collected | Source |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Klover |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Supplier | Transportation Laboratory (TL) Number | Vendor submitted |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 087-110 |
---|---|---|---|
Batch number | 3367 | Mix number | 3367 |
Test Details
DIME Sample ID: 2019-04-05-12
DIME Test ID: 2019-04-05-12-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2019-04-23
Test Results
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 04/16/2019
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 25 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 8 %
Flash point (ASTM D 3828) more than 180 deg F: 190 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 829 psi
Tack free time, 400 minutes max: 0 minutes
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/23/2019 ✔