Summary for Test 2019-03-29-15-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Sample Information

Sample Taken Date03/29/2019 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/29/2019
Sample typeVerification A brief description of the sample1/2-inch Untreated Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byTheodore Last name of sampler or witnessed byKinsey
Title of sampler Telephone number of sampler
Laboratory sample identificationD77809A Linked DIME Sample ID
The fabricator/manufacturer/facility nameFawndale Rock and Asphalt Transportation Laboratory (TL) Number001576
Inspector Lot Number from the Transportation Laboratory (TL) Form0 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0017::FAWNDALE ROCK QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample19-1001.314
The plant numberUnknown A detailed description of where the material sample was collectedUntreated Aggregate Stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 19-03-S1 Lot number0
Sublot number0 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-29-15
DIME Test ID: 2019-03-29-15-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-04-29

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 04/02/2019
Cumulative Mass RetainedCumulative Percent Passing
3440 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
638.0 grams81.5 %
2523.0 grams26.7 %
3234 grams6 %
3292.0 grams4.3 %
55.5 grams2.7 %
75.8 grams2.1 %
85.9 grams1.8 %
92.9 grams1.6 %
99.5 grams1.4 %
106.3 grams1.21 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/29/2019