Test 2019-03-13-18-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date3/13/2019 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/27/2019
Sample typeVerification A brief description of the sampleBags of Aggregate
The quantity of what the sample constitutes4 bags From where was the sample collectedOther
First name of sampler or witnessed byBrent Last name of sampler or witnessed byBarber
Title of samplerField Inspector Laboratory sample identification19-J-015
The fabricator/manufacturer/facility namePapich Paso Robles Transportation Laboratory (TL) NumberD5
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-10-0006::AVENAL AGGREGATES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedHot Drop at the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-03-13-18
DIME Test ID: 2019-03-13-18-1
Testing Lab: CT D05 - Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-04-22
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 04/03/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:84 %
Cumulative percent passing the 3/8 in. sieve:71 %
Cumulative percent passing the 1/4 in. sieve:60 %
Cumulative percent passing the #4 sieve:50 %
Cumulative percent passing the #8 sieve:34 %
Cumulative percent passing the #16 sieve:22 %
Cumulative percent passing the #30 sieve:15 %
Cumulative percent passing the #50 sieve:10 %
Cumulative percent passing the #100 sieve:7 %
Cumulative percent passing the #200 sieve:4.6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/22/2019