Summary for Test 2019-03-07-16-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 212816 DEA: 020H6304 EFIS: 0215000063 |
---|---|
DIST-CO-RTE-PM | 02-LAS-139-6.2/7.3 |
Award Date | 06/29/2018 |
Closeout Date | 12/04/2019 |
Work Description | ROADWAY EXCAVATION, AGGREGATE BASE, HOT MIX ASPHALT, GUARDRAIL |
Location Description | LASSEN COUNTY ABOUT 6 MILES NORTH OF SUSANVILLE FROM 1.0 MILE SOUTH TO 0.1 MILE SOUTH OF ANTELOPE RADIO STREET |
QA Service Level | 1 (Verified on 01/17/2018) |
Sample Information
Sample Taken Date | 03/07/2019 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/07/2019 |
Sample type | Quality Control | A brief description of the sample | Lime |
The quantity of what the sample constitutes | Mix Design | From where was the sample collected | Source |
First name of sampler or witnessed by | KRC | Last name of sampler or witnessed by | KRC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Lhoist North America | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Antistrip Additive | Antistrip Type | Lime - hydrated lime |
---|---|---|---|
Antistrip Additive Mix Number | Not set |
Test Details
DIME Sample ID: 2019-03-07-16
DIME Test ID: 2019-03-07-16-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-04-09
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Assumed
Date of test: 03/07/2019
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the 1/4 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 100 %
Cumulative percent passing the #16 sieve: 100 %
Cumulative percent passing the #30 sieve: 97 %
Cumulative percent passing the #50 sieve: 92 %
Cumulative percent passing the #100 sieve: 86 %
Cumulative percent passing the #200 sieve: 80 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2019 ✔