Summary for Test 2019-03-27-4-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 213817 DEA: 120Q9104 EFIS: 1217000126 |
---|---|
DIST-CO-RTE-PM | 12-ORA-55,261-Var |
Award Date | 02/08/2019 |
Closeout Date | 07/02/2021 |
Work Description | METHACRYLATE BRIDGE DECK SEAL TREATMENT AND PAVEMENT DELINEATION. |
Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/02/2021) |
Sample Information
Sample Taken Date | 03/27/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2019 |
Sample type | Quality Control | A brief description of the sample | 2 pints 204,chp,zcure,8020 |
The quantity of what the sample constitutes | 25000 gallons | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Nunes |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | kwik Bond, Benecia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 1811889988 |
---|---|---|---|
Batch number | 1811889988 | Mix number | 1811889988 |
Test Details
DIME Sample ID: 2019-03-27-4
DIME Test ID: 2019-03-27-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2019-04-05
Test Results
Input Type: Measured
Tester's full name: Larry McCrum
Date of test: 04/05/2019
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.3
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.13
Volatile content (ASTM D 2369) 30% max: 19.3
Flash point (ASTM D 3828) more than 180 deg F: 275
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 914
Tack free time, 400 minutes max: 300
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/5/2019 ✔