Test 2019-03-25-17-7 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 212889
DEA: 073009U4
EFIS: 0714000238
DIST-CO-RTE-PM07-LA-110-R0.7/24.1
Work DescriptionREPLACE CONCRETE PAVEMENT, COLD PLANE AND PLACE HMA PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES AND CARSON FROM GAFFEY STREET TO 0.1 MILE SOUTH OF COLLEGE STREET OVERCROSSING
Sample Information
Sample Taken Date3/25/2019 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/25/2019
Sample typeVerification A brief description of the sampleCombined Cold Feed
The quantity of what the sample constitutesJMF 3 bags cold feed From where was the sample collectedManufacturer
First name of sampler or witnessed byG Last name of sampler or witnessed byZubieta
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameAAA-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedHot Bins
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2019-52
Test Details
DIME Sample ID: 2019-03-25-17
DIME Test ID: 2019-03-25-17-7
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-04-04
Test Results

What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 03/29/2019
Bulk dry specific gravity: 2.637
Average uncompacted voids:47 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/04/2019