Summary for Test 2019-03-21-1-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 212726 DEA: 030F3514 EFIS: 0316000080 |
---|---|
DIST-CO-RTE-PM | 03-SAC-51,99-VAR |
Award Date | 02/08/2018 |
Closeout Date | 12/08/2021 |
Work Description | ROADWAY EXCAVATION, HOT MIX ASPHALT AND MODIFY ELECTRICAL SYSTEM; SOLDIER PILES; CONCRETE RETAINING WALL |
Location Description | SACRAMENTO COUNTY FROM 0.5 MILE SOUTH OF COSUMNES RIVER BOULEVARD TO 0.2 MILE EAST OF ARDEN WAY UNDERCROSSING |
QA Service Level | 1 (Verified on 04/02/2018) |
Sample Information
Sample Taken Date | 03/21/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/25/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts |
The quantity of what the sample constitutes | 75 pcs | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | Telephone number of sampler | 3609216934 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Blue Circle Nucor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-058-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1201006809 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 | |
Bolt Length(s) | Nut Specification | N/A | |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 2 1/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-03-21-1
DIME Test ID: 2019-03-21-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-04-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/02/2019
UTM: 67KIP
Temperature: 72 f
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1201006809 | 0.502 | 0.198 | 59173 | 81820 | 28 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/2/2019 ✔