Summary for Test 2019-03-07-2-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213664
DEA: 042Q9804
EFIS: 0419000118
DIST-CO-RTE-PM04-CC,CC,SOL-680-25.1/25.5, 0.0/0.9
Award Date10/16/2018
Closeout Date12/17/2019
Work DescriptionRepair expansion joint assembly
Location DescriptionNot set
QA Service Level1 (Verified on 10/24/2018)

Sample Information

Sample Taken Date03/07/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/08/2019
Sample typeQuality Assurance A brief description of the sampleA352 Bolt/Nut/washer Assy
The quantity of what the sample constitutes2 lots From where was the sample collectedDistributor
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler9252121984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBay Bolt, Nucor, TSI, Loc-Mor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-011-19 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)6504-01 3 6504-02 3 and one quarter
Heat Number(s)3 inch 100785759 3 and one quarter NF14202676 Nut Mfg. Lot Number(s)3402012
Washer Mfg. Lot Number(s)0218-761 Bolt SpecificationA325
Bolt Length(s)3" and 3.25" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1/2" Bolt Mfg. Lot Number3 inch 384118A 3 and one quarter 34712A
Rocap Test Requirement(s)Long bolt test Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2019-03-07-2
DIME Test ID: 2019-03-07-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-03-20

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/12/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A384118A1/2\"1940986.310A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 3/13/2019