Summary for Test 2019-01-29-14-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R3.8/R11.7 |
Award Date | 11/06/2018 |
Closeout Date | 08/16/2023 |
Work Description | WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB |
Location Description | SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
Sample Taken Date | 01/29/2019 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/01/2019 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (eq. PG 64-10/16) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Ortiz |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D77789 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Fawndale Rock and Asphalt - Redding, CA | Transportation Laboratory (TL) Number | 736644 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 0 |
Sublot number | 0 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-01-29-14
DIME Test ID: 2019-01-29-14-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-02-25
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 02/01/2019
Method Performed: no data
Mass of container filled with water: 7371.0 grams
Mass of oven-dry sample in air for Sample 1: 2623.0 grams
Mass of container filled with the sample and water for Sample 1: 8989.0 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.609
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/25/2019 ✔