Summary for Test 2019-02-07-4-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213074
DEA: 044G8904
EFIS: 0413000059
DIST-CO-RTE-PM04-CC-580-5.8
Award Date05/10/2018
Closeout Date03/12/2020
Work DescriptionBIDGE SEISMIC RETROFIT
Location DescriptionCONTRA COSTA COUNTY IN RICHMOND AT SCOFIELD AVENUE UNDERCROSSING
QA Service Level1 (Verified on 02/13/2018)

Sample Information

Sample Taken Date02/07/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/07/2019
Sample typeQuality Assurance A brief description of the sampleAnchor Rods
The quantity of what the sample constitutes13 From where was the sample collectedFabricator
First name of sampler or witnessed byAndre Last name of sampler or witnessed byTotari
Title of samplerASMR Telephone number of sampler(510) 730-0387
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCosmec Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)DL18104836, DL16102749, 176411 Nut Mfg. Lot Number(s)381629A,
Washer Mfg. Lot Number(s)312021 Bolt SpecificationA449 threaded rod
Bolt Length(s)16", 12.5", 12", 8.75", 7.5" Nut SpecificationA194-2H HDG
Washer SpecificationF436 HDG FinishHDG
Diameter/Size1" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-02-07-4
DIME Test ID: 2019-02-07-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-02-22

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 02/13/2019
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A381629A1\"93427415.58nut proofSteve

General comments (publicly viewable) (Max 1000 characters): nut proof
Test Graph
Source: Partner Data Point File

Test was verified on 2/15/2019