Test 2019-02-13-1-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 9999
DEA: 00000000
EFIS: 0000000000
COOP: 99999333399
MINOR: 333333
Permit Numbers: 555555 0400NRT0000
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Sample Information
Sample Taken Date2/13/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/13/2019
Sample typeQuality Control A brief description of the sampleTest
The quantity of what the sample constitutes1 From where was the sample collectedSource
First name of sampler or witnessed byTest Last name of sampler or witnessed byTest
Title of samplerTest Laboratory sample identificationTest
The fabricator/manufacturer/facility nameTest Transportation Laboratory (TL) NumberTest
Inspector Lot Number from the Transportation Laboratory (TL) FormTest Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Test
The fabricator's/manufacturer's product name for the sampleTest The fabricator/manufacturer designation for the sampleUnknown
The plant numberTest A detailed description of where the material sample was collectedTest
Where the material sample would have been placed if not sampledTest Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot number1
Sublot number1 HMA Design ID JMF3512-2019-74-TEST
Test Details
DIME Sample ID: 2019-02-13-1
DIME Test ID: 2019-02-13-1-1
Testing Lab: CT HQ - Hot Mix Asphalt Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-02-20
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 02/13/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:200 %
Cumulative percent passing the 3/4 in. sieve:88 %
Cumulative percent passing the 1/2 in. sieve:31 %
Cumulative percent passing the 3/8 in. sieve:3 %
Cumulative percent passing the 1/4 in. sieve:3 %
Cumulative percent passing the #4 sieve:1 %
Cumulative percent passing the #8 sieve:1 %
Cumulative percent passing the #16 sieve:0.5 %
Cumulative percent passing the #30 sieve:0 %
Cumulative percent passing the #50 sieve:0 %
Cumulative percent passing the #100 sieve:0 %
Cumulative percent passing the #200 sieve:0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 02/13/2019