Summary for Test 2018-12-17-11-1

Test performed: CTM 202-Oct 2014

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/17/2018 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/17/2018
Sample typeQuality Control A brief description of the sample3/8"
The quantity of what the sample constitutesJMF From where was the sample collectedSource
First name of sampler or witnessed byCarlos Last name of sampler or witnessed byManzo
Title of samplerQC Technician Telephone number of sampler805-440-7390
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPM-Avenal Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006::AVENAL AGGREGATES
The fabricator's/manufacturer's product name for the sample3/8 The fabricator/manufacturer designation for the sample3/8 Crushed
The plant number1 A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberTEM34SPLA Lot number1
Sublot number1 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2018-12-17-11
DIME Test ID: 2018-12-17-11-1
Testing Lab: Sierra Pacific Materials
Test Method: CTM 202-Oct 2014: Method of Test for Determining Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-02-12

Test Results


What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Input Type: Calculated
Tester's full name: unknown
Date of test: 12/17/2018
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 85 %
Cumulative percent passing the #4 sieve: 18 %
Cumulative percent passing the #8 sieve: 2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/12/2019