Summary for Test 2019-01-15-2-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date01/15/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/17/2019
Sample typeQuality Assurance A brief description of the sampleASTM A325 3/4 - 4"
The quantity of what the sample constitutes135 From where was the sample collectedDistributor
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Inspector Telephone number of sampler707-342-8602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameIndustrial Bolt and Supply Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-005-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)RC0033427
Heat Number(s)10514140 Nut Mfg. Lot Number(s)29387-S
Washer Mfg. Lot Number(s)D5483 Bolt SpecificationASTM A325
Bolt Length(s)4" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishGalvanized
Diameter/Size3/4" x 4" Bolt Mfg. Lot NumberBG1058
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-01-15-2
DIME Test ID: 2019-01-15-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-01-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/23/2019
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A29387-5-6214786102?\"51090227.26Nut Proof LoadFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 1/23/2019