Summary for Test 2019-01-14-4-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212888 DEA: 07202124 EFIS: 0700020870 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-20.9/24.6 |
Award Date | 02/16/2018 |
Closeout Date | 05/04/2022 |
Work Description | PAVEMENT REHABILITATION AND BRIDGE WIDENING |
Location Description | LOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING |
QA Service Level | 1 (Verified on 03/29/2018) |
Sample Information
Sample Taken Date | 01/14/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/14/2019 |
Sample type | Quality Assurance | A brief description of the sample | HRC 500/510 |
The quantity of what the sample constitutes | 256 Bars | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
Title of sampler | QA | Telephone number of sampler | 310-883-8369 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Etiwanda | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-001-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | CMC Rebar Etiwanda |
Rebar Size | 14 | Coupler Model | HRC 500 /510 XTender |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | NA | Rebar Hoop Fabricator | NA |
Coupler Component Heat/Lot Number(s) | A162884 / 73101431 | Rebar Heat Number(s) | 6502943903 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2019-01-14-4
DIME Test ID: 2019-01-14-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-01-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/18/2019
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #14/43mm | 2.25 | 0 | 233924 | 103970 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/18/2019 ✔