Summary for Test 2019-01-08-1-5

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212185
DEA: 024G5204
EFIS: 0214000022
DIST-CO-RTE-PM02-SHA-5-R28.0 - R29.2
Award Date05/21/2018
Closeout Date09/02/2020
Work DescriptionPIT RIVER BRIDGE DECK & CATWALK REHABILITATION
Location DescriptionSHASTA COUNTY ABOUT 6 MILES NORTH OF SHASTA LAKE FROM 0.2 MILE SOUTH TO 0.9 MILE NORTH OF PIT RIVER BRIDGE OVERHEAD
QA Service Level1 (Verified on 06/05/2017)

Sample Information

Sample Taken Date01/08/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2019
Sample typeQuality Assurance A brief description of the sampleA325 Fastener Assembly
The quantity of what the sample constitutes20 From where was the sample collectedJob Site
First name of sampler or witnessed byJordan Last name of sampler or witnessed byWebb
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100791937, NF09100475, NF13104445, NF15101674, 100889865, 176414 Nut Mfg. Lot Number(s)407093A
Washer Mfg. Lot Number(s)310706 Bolt SpecificationA325 MG
Bolt Length(s)2.25", 2.5" Nut SpecificationDH MG
Washer SpecificationF436 MG FinishMG
Diameter/Size5/8 Bolt Mfg. Lot Number411418A, 260531A, 338564A, 365183A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-01-08-1
DIME Test ID: 2019-01-08-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-01-17

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/09/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
13A338564A5/8\"31535140.310A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 1/10/2019