Summary for Test 2019-01-07-2-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211235 DEA: 054482U4 EFIS: 0500000543 |
---|---|
DIST-CO-RTE-PM | 05-SB-101-2.2/3.3 |
Award Date | 06/20/2016 |
Closeout Date | 08/23/2021 |
Work Description | BUILD AND RECONSTRUCT BRIDGES, CONSTRUCT RAMPS AND FRONTAGE ROAD. |
Location Description | SANTA BARBARA COUNTY IN CARPINTERIA FROM 0.2 MILE SOUTH OF CARPINTERIA CREEK BRIDGE TO FRANKLIN CREEK BRIDGE |
QA Service Level | 1 (Verified on 07/27/2016) |
Sample Information
Sample Taken Date | 01/07/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/08/2019 |
Sample type | Retest | A brief description of the sample | #5 Bartec couplers |
The quantity of what the sample constitutes | 150 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-101-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Retest |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Dextra America | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 5 | Coupler Model | 2844 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | NFF11100166B | Rebar Heat Number(s) | SE1810075001 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2019-01-07-2
DIME Test ID: 2019-01-07-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-01-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/09/2019
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | C18 | #5/16mm | 0.31 | 0 | 28474 | 91852 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/9/2019 ✔