Test 2018-10-01-12-3 (CTM 527-February 2014) Summary

Project Information
Project IdentifiersProject ID: 212577
DEA: 11408704
EFIS: 1112000017
DIST-CO-RTE-PM11-SD-8-9.0/15.3
Work DescriptionSLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL.
Location DescriptionSAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON
Sample Information
Sample Taken Date10/1/2018 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/1/2018
Sample typeAcceptance A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedJob Site
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of samplerUnknown Laboratory sample identificationCM184801
The fabricator/manufacturer/facility nameCMAX Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeCementitious BrandCMAX
MillUnknown Type of Cementitious MaterialRapid Set Cement
Test Details
DIME Sample ID: 2018-10-01-12
DIME Test ID: 2018-10-01-12-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 527-February 2014: Method of Test for Expansion in Water and Contraction in Air of Portland Cement Mortar
Test Release Date: 2019-01-21
Test Results

Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 10/19/2018
Initial Length of Specimen 1: .2547 in
Expansion Length of Specimen 1: .2554 in
Percent Expansion of Specimen 1: 100.27 %
Contraction Length of Specimen 1: .2518 in
Percent Contraction of Specimen 1: 98.86 %
Initial Length of Specimen 2: .2587 in
Expansion Length of Specimen 2: .2593 in
Percent Expansion of Specimen 2: 100.23 %
Contraction Length of Specimen 2: .2559 in
Percent Contraction of Specimen 2: 98.92 %
Initial Length of Specimen 3: .2663 in
Expansion Length of Specimen 3: .2670 in
Percent Expansion of Specimen 3: 100.26 %
Contraction Length of Specimen 3: .2634 in
Percent Contraction of Specimen 3: 98.91 %
Initial Length of Specimen 4: .3038 in
Expansion Length of Specimen 4: .3045 in
Percent Expansion of Specimen 4: 100.23 %
Contraction Length of Specimen 4: .3010 in
Percent Contraction of Specimen 4: 99.08 %
Average change in length in water: 50.12 %
Average change in length in air: 49.50 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 01/14/2019