Test 2018-12-28-4-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 211235
DEA: 054482U4
EFIS: 0500000543
DIST-CO-RTE-PM05-SB-101-2.2/3.3
Work DescriptionBUILD AND RECONSTRUCT BRIDGES, CONSTRUCT RAMPS AND FRONTAGE ROAD.
Location DescriptionSANTA BARBARA COUNTY IN CARPINTERIA FROM 0.2 MILE SOUTH OF CARPINTERIA CREEK BRIDGE TO FRANKLIN CREEK BRIDGE
Sample Information
Sample Taken Date12/28/2018 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/1/2019
Sample typeQuality Assurance A brief description of the sampleBarsplice Zap Screwlok Coupler & Bartec Couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byEmiliano Last name of sampler or witnessed byBerntsen
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameBarsplice, Dextra America, Nucor Transportation Laboratory (TL) NumberC760334
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarsplice Dextra America Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelZap Screwlok dextra America
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)71077746, 2844 Rebar Heat Number(s)SE1810075001
Rebar Size 2
Test Details
DIME Sample ID: 2018-12-28-4
DIME Test ID: 2018-12-28-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-01-10
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/02/2019
UTM: 400KIP
Halo ID: Small
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#5/16mm0.3102899893542Service spliceFred

General comments (publicly viewable) (Max 250 characters): Service splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 01/03/2019