Test 2018-12-20-1-1 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 212888
DEA: 07202124
EFIS: 0700020870
DIST-CO-RTE-PM07-LA-710-20.9/24.6
Work DescriptionPAVEMENT REHABILITATION AND BRIDGE WIDENING
Location DescriptionLOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING
Sample Information
Sample Taken Date12/20/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Assurance A brief description of the sampleSCC concrete
The quantity of what the sample constitutes5 yards From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerQuality Assurance Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameCon-Fab California Corporation Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS47-002-18 Structure unique identifier
Structure nameH310D
Material Information
Material TypeConcrete The concrete mix design numberSCCS9525F
The truck number from where the sample was collectedxxx The batch plant ticket number from where the sample was collectedxxx
Concrete batch plantConFab Shafter The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedChute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2018-12-20-1
DIME Test ID: 2018-12-20-1-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-12-27
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: RM
Date of test: 12/27/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 306081 lb
Maximum load on cylinder 2: 299168 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 10754.8 psi
Compressive strength of cylinder 2: 10545.2 psi
Compressive strength (to nearest 10 psi):10650 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 12/27/2018