Summary for Test 2018-05-24-14-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 212562
DEA: 024G5504
EFIS: 0214000036
DIST-CO-RTE-PM02-SIS-5-2.7/R11.4
Award Date03/12/2018
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS
Location DescriptionSISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS
QA Service Level1 (Verified on 04/04/2018)

Sample Information

Sample Taken Date05/24/2018 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/24/2018
Sample typeVerification A brief description of the sample3/4-inch Type A HMA (PG 64-28)
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byChandler Last name of sampler or witnessed byFaeth
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationD77419-1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameFawndale Rock and Asphalt - Redding, CA Transportation Laboratory (TL) Number897213
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-14-S2 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-24-14
DIME Test ID: 2018-05-24-14-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2018-12-19

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 06/04/2018
Specimen Treatment: Treated
Average Dry Tensile Strength: 120 psi
Average Wet Tensile Strength: 133 psi
Tensile Strength Ratio: 110
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/19/2018