Summary for Test 2018-12-11-1-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 213516 DEA: 101H3414 EFIS: 1018000077 |
---|---|
DIST-CO-RTE-PM | 10-SJ-5-R21.4 |
Award Date | 10/04/2018 |
Closeout Date | 01/24/2020 |
Work Description | GIRDER REPAIR. |
Location Description | SAN JOAQUIN COUNTY AT FRENCH CAMP AT MATHEWS ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 11/01/2018) |
Sample Information
Sample Taken Date | 12/11/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2018 |
Sample type | Quality Assurance | A brief description of the sample | .6" 270ksi strand |
The quantity of what the sample constitutes | 2 partial packs | From where was the sample collected | Source |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Schwager-Davis | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-105-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S378233-4 S334180-2 | Number of Coils | 2 partials |
Group Number | Unknown | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0201504 s0520317 | Mfg. Lot Number(s) | unknown at this time |
Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2018-12-11-1
DIME Test ID: 2018-12-11-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-12-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/19/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0520317 | S334180-2 | 0.215 | 61214 | 55908 | 28.8 | 1.74 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 12/20/2018 ✔