Summary for Test 2018-10-19-1-1

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 212600
DEA: 07293704
EFIS: 0713000239
DIST-CO-RTE-PM07-LA-110,405-8.0/9.0,12.2/13.2
Award Date02/27/2018
Closeout Date08/03/2023
Work DescriptionWIDEN SHOULDER AND AUXILIARY LANE OF CONNECTOR.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR CARSON ON ROUTE 110 FROM 0.2 MILE NORTH OF TORRANCE BOULEVARD UNDERCROSSING TO 190TH STREET UNDERCROSSING AND ON ROUTE 405 FROM MAIN STREET UNDERCROSSING TO 190TH STREET UNDERCROSSING
QA Service Level1 (Verified on 04/03/2018)

Sample Information

Sample Taken Date10/19/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2018
Sample typeQuality Assurance A brief description of the sampleA615 Grade 75 Threaded Bar with A108 Nut
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed byWeeks
Title of samplerQA Telephone number of sampler310-883-8369
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form San Diego Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL79-084-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar Type Rebar Size9
Nut Specification for Threaded BarASTM A108 System ManufacturerWilliams Form Engineering
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)100791754
Nut Heat Number(s)8294599 Bar Lot Number10070175421
Nut Lot Number9H9D Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-10-19-1
DIME Test ID: 2018-10-19-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-10-31

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/24/2018
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
11#9 A615 Threaded Bar and NutL79-084-1811189508472310.8A615 Threaded Bar and NutBrian

General comments (publicly viewable) (Max 1000 characters): A615 Threaded Bar and Nut
Test Graph
Source: Partner Data Point File

Test was verified on 10/24/2018