Summary for Test 2018-10-03-24-9

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212562
DEA: 024G5504
EFIS: 0214000036
DIST-CO-RTE-PM02-SIS-5-2.7/R11.4
Award Date03/12/2018
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS
Location DescriptionSISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS
QA Service Level1 (Verified on 04/04/2018)

Sample Information

Sample Taken Date10/03/2018 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/10/2018
Sample typeQuality Assurance A brief description of the samplefastener Assembly
The quantity of what the sample constitutes8 Rocaps From where was the sample collectedManufacturer
First name of sampler or witnessed byJoe Last name of sampler or witnessed byAdame
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameStructural Steel Products Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormS43-046-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)091718D, 091718E, 091718B, 091718F, 091718G, 142, 143
Heat Number(s)NA Nut Mfg. Lot Number(s)406665A, 402866A, 363890A, 23501-166333
Washer Mfg. Lot Number(s)D3078, D4240, D2602, D4382 Bolt SpecificationA325
Bolt Length(s)2.25, 2.5, 1.5, 2.75, 3.75, 4, 4.25 Nut SpecificationA563
Washer SpecificationF436 FinishMG
Diameter/Size.75, .625, .5, 1.25, 1.5 Bolt Mfg. Lot Number406659B, 404840A, 404784A, 400036A, 361722A,
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2018-10-03-24
DIME Test ID: 2018-10-03-24-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-10-30

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/19/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
16A407005A1.250\"127775568.46A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 10/23/2018