Summary for Test 2018-10-02-6-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 212345 DEA: 044G2204 EFIS: 0412000314 |
---|---|
DIST-CO-RTE-PM | 04-SON-12-17.75-18.20 |
Award Date | 12/06/2017 |
Closeout Date | 03/12/2021 |
Work Description | PROJECT: SONOMA 12 FARMERS LANE MEDIAN BARRIER MICROPILES |
Location Description | IN SONOMA COUNTY ON ROUTE 12, IN SANTA ROSA FROM FARMERS LANE TO BRUSH CREEK RD. |
QA Service Level | 1 (Verified on 10/18/2017) |
Sample Information
Sample Taken Date | 10/02/2018 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/05/2018 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Harry | Last name of sampler or witnessed by | Suryantoro |
Title of sampler | Transportation Engineer | Telephone number of sampler | 1-707-333-4263 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Shamrock Materials | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 4158CR |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 469576 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2018-10-02-6
DIME Test ID: 2018-10-02-6-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-10-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Larry McCrum
Date of test: 10/12/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 105903 lb
Maximum load on cylinder 2: 108885 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 10 days
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3708.1 psi
Compressive strength of cylinder 2: 3838.0 psi
Compressive strength (to nearest 10 psi): 3770 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/12/2018 ✔