Test 2018-10-04-1-2 (ASTM A722-15) Summary

Project Information
Project IdentifiersProject ID: 213205
DEA: 051J6704
EFIS: 0518000010
DIST-CO-RTE-PM05-SB-192-15.4/15.6
Work DescriptionReplace bridge and restore roadway
Location DescriptionArroyo Paredon Bridge
Sample Information
Sample Taken Date10/4/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/5/2018
Sample typeQuality Assurance A brief description of the sampleATB A722 1-3/8
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byCarolina Last name of sampler or witnessed byMargarito
Title of samplerAsst METS Rep Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameWFE Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL73-020-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar Type Rebar Size
Nut Specification for Threaded BarA29 System ManufacturerNot Available
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)62139760
Nut Heat Number(s)75071080 Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)Unknown
Coupler GradeUnknown
Test Details
DIME Sample ID: 2018-10-04-1
DIME Test ID: 2018-10-04-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-10-18
Test Results

Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/11/2018
UTM: 400KIP
Temperature:72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
12A722 1.375\" Threaded Bar & NutL73-020-181.581656671318336.40A722 Threaded Bar and NutBrian

General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 10/11/2018