Summary for Test 2018-10-04-4-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211784 DEA: 11085784 EFIS: 1100000064 |
---|---|
DIST-CO-RTE-PM | 11-SD-163-4.1/4.9 |
Award Date | 06/16/2017 |
Closeout Date | 08/10/2021 |
Work Description | INTERCHANGE MODIFICATION AND OVERCROSSING WIDENING. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 09/05/2017) |
Sample Information
Sample Taken Date | 10/04/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/22/2018 |
Sample type | Quality Assurance | A brief description of the sample | Erico Lenton Stander Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Carlos | Last name of sampler or witnessed by | Flatiron |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Erico | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | Erico Lenton | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 8 | Coupler Model | EL28A2 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | L8966 | Rebar Heat Number(s) | 4079268 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-10-04-4
DIME Test ID: 2018-10-04-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-10-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/05/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #8/25mm | 0.79 | -0.0016 | 70974 | 89841 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/23/2018 ✔