Summary for Test 2018-09-17-1-3

Test performed: ASTM F606-14

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/17/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/19/2018
Sample typeVerification A brief description of the sampleA449 HDG anchor bolt
The quantity of what the sample constitutes10 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCT METS QA INSPECTOR Telephone number of sampler801-669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-187-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)none
Heat Number(s)62146593 Nut Mfg. Lot Number(s)n/a
Washer Mfg. Lot Number(s)n/a Bolt SpecificationA449
Bolt Length(s)17 1/2" Nut Specificationn/a
Washer Specificationn/a FinishHDG
Diameter/Size7/8" x 17 1/2' Bolt Mfg. Lot Number31228 Rockford
Rocap Test Requirement(s)none Lubricant Requirements(s)none

Test Details

DIME Sample ID: 2018-09-17-1
DIME Test ID: 2018-09-17-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-10-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/27/2018
UTM: 400KIP
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11C7/8 \" A449 Bolt, 10 Degree Wedge0.4626657929614411014039064860Head Popped Off

General comments (publicly viewable) (Max 1000 characters): Head Popped Off
Test Graph
Source: Partner Data Point File

Test was verified on 9/27/2018