Summary for Test 2018-09-12-9-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 212726 DEA: 030F3514 EFIS: 0316000080 |
---|---|
DIST-CO-RTE-PM | 03-SAC-51,99-VAR |
Award Date | 02/08/2018 |
Closeout Date | 12/08/2021 |
Work Description | ROADWAY EXCAVATION, HOT MIX ASPHALT AND MODIFY ELECTRICAL SYSTEM; SOLDIER PILES; CONCRETE RETAINING WALL |
Location Description | SACRAMENTO COUNTY FROM 0.5 MILE SOUTH OF COSUMNES RIVER BOULEVARD TO 0.2 MILE EAST OF ARDEN WAY UNDERCROSSING |
QA Service Level | 1 (Verified on 04/02/2018) |
Sample Information
Sample Taken Date | 09/12/2018 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/20/2018 |
Sample type | Quality Assurance | A brief description of the sample | ASTM F1554 Grade 55 All Thread Rod |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | C874455 C874456 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S43-042-18 S43-043-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | PL17100076 PL16207513 | Nut Mfg. Lot Number(s) | 28588-S-6214658903 28769-6214705402 |
Washer Mfg. Lot Number(s) | NA | Bolt Specification | F1554 |
Bolt Length(s) | 10.5 10 | Nut Specification | A563 |
Washer Specification | NA | Finish | HDG |
Diameter/Size | .875 .75 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-09-12-9
DIME Test ID: 2018-09-12-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-10-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/26/2018
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | F1554 All Thread Rod Gr 55 | 0.462 | 41636 | 185 | 90121 | 71216 | 32902 | F1554 All Thread Rod Gr 55 |
General comments (publicly viewable) (Max 1000 characters): F1554 All Thread Rod Gr 55
Test Graph
Source: Partner Data Point FileTest was verified on 9/26/2018 ✔