Summary for Test 2018-09-18-4-3
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 211982 DEA: 060K4604 EFIS: 0612000105 |
---|---|
DIST-CO-RTE-PM | 06-KER-46,99-57.3/57.8,43.9/44.6 |
Award Date | 05/05/2017 |
Closeout Date | 10/17/2019 |
Work Description | REALIGN ROADWAY AND CONSTRUCT NEW BRIDGE. |
Location Description | KERN COUNTY NEAR FAMOSO ON ROUTE 46 FROM 0.5 MILE WEST OF ROUTE 46/99 SEPARATION TO 0.1 MILE EAST OF ROUTE 46/99 SEPARATION AND ON ROUTE 99 FROM 0.4 MILE SOUTH OF ROUTE 46/99 SEPARATION TO 0.3 MILE NORTH OF ROUTE 46/99 SEPARATION |
QA Service Level | 1 (Verified on 06/26/2017) |
Sample Information
Sample Taken Date | 09/18/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2018 |
Sample type | Quality Assurance | A brief description of the sample | Headed Bars |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Rene | Last name of sampler or witnessed by | Raynes |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Gerdau | Transportation Laboratory (TL) Number | C819458 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Rebar Heat Number(s) | 6503216002 | Head Manufacturer Lot Number(s) | 1, 2 |
Rebar Size | 6 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | Gerdau |
Head Manufacturer | HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2018-09-18-4
DIME Test ID: 2018-09-18-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-10-03
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/24/2018
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 0.44 | 46030 | 104610 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 9/26/2018 ✔