Summary for Test 2018-09-10-4-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 212910 DEA: 080K2914 EFIS: 0812000098 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-30.9/33.3 |
Award Date | 03/06/2018 |
Closeout Date | 09/04/2019 |
Work Description | LANE REPLACEMENT |
Location Description | SAN BERNARDINO COUNTY IN REDLANDS FROM ORANGE STREET UNDERCROSSING TO REDLANDS BLVD OFF-RAMP UNDERCROSSING |
QA Service Level | 1 (Verified on 05/02/2018) |
Sample Information
Sample Taken Date | 09/10/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/17/2018 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | manny | Last name of sampler or witnessed by | Alcorta |
Title of sampler | quality technician | Telephone number of sampler | Unknown |
Laboratory sample identification | 987-091018 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Security Paving company | Transportation Laboratory (TL) Number | 091018 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | for Cemex mix design number 1419984 |
Structure name | for Cemex mix design number 1419984 |
Material Information
Material Type | Concrete | The concrete mix design number | 1419984 |
---|---|---|---|
The truck number from where the sample was collected | na | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Security Paving company |
A detailed description of where the material sample was collected | concrete plant | Where the material sample would have been placed if not sampled | for Cemex mix design number 1419984 |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-09-10-4
DIME Test ID: 2018-09-10-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-09-24
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MC
Date of test: 09/17/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 5.97 in
Maximum load on cylinder 1: 35940 lb
Maximum load on cylinder 2: 37810 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Compressive strength of cylinder 1: 1271.3 psi
Compressive strength of cylinder 2: 1350.8 psi
Compressive strength (to nearest 10 psi): 1310 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/17/2018 ✔